Determination of the specific gravity of a solution of uranyl nitrate

Scope

This method covers the determination of the specific gravity of a solution of uranyl nitrate to ± 0.0004

Summary of method

A known volume of the solution adjusted at a controlled temperature is weighed and compared to the weight of water measured in the same container.

Equipments

  • Volumetric Flask, 50-mL, class A

  • Water Bath, temperature controlled to ± 0.1 oC at a temperature slightly above

  • normal room temperature, and provided with clips for holding volumetric flasks.

Procedure

  • Weigh the clean, dry volumetric flask and its stopper to the nearest 0.1 mg

  • Fill the volumetric flask with the uranyl nitrate solution to a point close to the volume mark, using a thin stemmed funnel and a glass dropper.

  • Place the stoppered volumetric flask in the water bath for 30 min.

  • Use a finely drawn glass dropper to adjust the liquid volume to the mark

  • Leave the flask in the water bath an additional 10 min to make sure that the bath temperature has been reached.

  • Dry and weigh the flask to the nearest 0.1 mg.

  • Repeat step 2 up to step 6 using boiled and cooled distilled water instead of the uranyl nitrate solution.

Calculation

Very accurate determinations of specific gravity require that vacuo corrections be made, but if a median correction figure in terms of grams of sample is applied to the solution weights in all cases the resulting error will not exceed 0.05%.


Sp gr = B-A + 0.0007(B-A)
C+A + 0.0010 (C-A)

B = sample plus flask in air, g
A = flask in air, g
C = water plus flask in air,g
0.007 g/g = correction factor applicable for densities of 1.3 to 1.5 and
0.0010 g/g = correction factor for water.

Precision

The limit of error at the 95% level for a singledetermination is ± 0.003%