Friday, February 20, 2009

Determination of atrazine and simazine in environmental water samples by dispersive liquid-liquid microextraction with high performance liquid chromat

Anal Sci. 2009 Jan;25(1):73-6.
Related Articles,
Links
Determination of atrazine and simazine in environmental water samples by dispersive liquid-liquid microextraction with high performance liquid chromatography.




Henan Normal University, Henan Key Laboratory for Environmental Pollution Control, Key Laboratory for Yellow River and Huaihe River Water Environment and Pollution Control, Ministry of Education and Pollution Control, Xinxiang, China. zhouqx@henannu.edu.cnThis paper describes a new method for the rapid and sensitive analysis of atrazine and simazine based on the dispersive liquid-liquid microextraction with carbon tetrachloride and methanol as the extraction solvent and disperser solvent. Under the optimal conditions, there are excellent linear relationships between the peak area and the concentration in the range of 0.5 - 50 microg L(-1) for atrazine and 0.1 - 50 microg L(-1) for simazine. The limits of detection were 0.1 and 0.04 microg L(-1) for atrazine and simazine, respectively. The proposed method was also applied to the analysis of real water samples, and excellent results were achieved with spiked recoveries in the range of 60.7 - 91.4%. All these results demonstrate that the proposed method would be widely used in many fields in the future.Publication Types:
Evaluation Studies
Research Support, Non-U.S. Gov'tPMID: 19139576 [PubMed - indexed for MEDLINE]